Configuration Guides for MiDAS DA


Get the technical information you need to configure your National Instruments hardware for use with MiDAS DA software. The MiDAS DA Application Notes listed below provide configuration information for specific models of National Instruments data acquisition devices.

MiDAS DA

Configuring the NI CB-68LP Screw Terminal Block for use with a 40-channel PCI PXI-6225 Board for MiDAS DA

This application note contains charts for wiring National Instruments CB-68LP screw terminal blocks for MiDAS DA hardware. This information applies to National Instruments M-Series device NI PCI/PXI-6255. Connections can be made for as many as 40 differential sensors or 80 single-ended sensors. This document also provides instructions for wiring trigger and sync out connections.

Configuring a National Instruments SC2345 50 Shielded Carrier for use with MiDAS DA

For Xcitex customers who wish to use MiDAS DA software with a National Instruments SC2345/50 Shielded Carrier, certain hardware connections are required. This application note describes the hardware connections for installing a National Instruments SC2345/50 Shielded Carrier for use with MiDAS DA.

Configuring the NI 6218-BNC USB DAQ Box for use with MiDAS DA

This application note describes the procedures for installing jumper cables and labels on a model 6218-BNC USB DAQ box from National Instruments for use with MiDAS DA.

Configuring the NI 6216-BNC USB DAQ Box for use with MiDAS DA

This application note describes the procedures for installing jumper cables and labels on a model 6216-BNC USB DAQ box from National Instruments for use with MiDAS DA.

Configuring NI USB BNC Boxes 6221, 6229, 6251, 6259 for use with MiDAS DA

This application note describes the procedure for installing jumper wires and labels on a customer-supplied USB BNC DAQ box from National Instruments for use with MiDAS DA. These instructions apply to models 6221, 6229, 6251, and 6259.

Configuring the NI BNC-2090 Rack Mount Box for use with MiDAS DA

This application note describes the hardware connections for installing a National Instruments Rack-Mounted BNC-2090 terminal block for use with MiDAS DA. While the BNC-2090 is not a standard accessory sold by Xcitex for use with MiDAS DA, it can easily be substituted for the standard BNC breakout box.

Configuring The NI BNC-2110 Breakout Box for use with MiDAS DA

This application note describes the procedure for installing jumper cables and labels on a customer-supplied BNC-2110 breakout box from National Instruments for use with MiDAS DA.

Configuring the NI CB-68LP Screw Terminal Block for use with 62xx M-Series Boards for MiDAS DA

This application note contains charts for wiring a National Instruments CB-68LP screw terminal block for MiDAS DA hardware. This information applies to National Instruments 62xx M-Series devices. Connections can be made for as many as 8 differential sensors or 16 single-ended sensors. This document also provides instructions for wiring trigger and sync out connections.

 